{"id":17187,"date":"2026-08-08T16:28:07","date_gmt":"2026-08-08T16:28:07","guid":{"rendered":"https:\/\/www.yulidapower.com\/?page_id=17187"},"modified":"2026-08-18T14:04:39","modified_gmt":"2026-08-18T14:04:39","slug":"power-bank-certifications-compliance","status":"publish","type":"page","link":"https:\/\/www.yulidapower.com\/es\/power-bank-certifications-compliance\/","title":{"rendered":"gu\u00eda de certificaciones y conformidad de power banks"},"content":{"rendered":"<style>\n.ycp{max-width:1120px;margin:auto;padding:20px 20px 70px;color:#1f2937;font-size:17px;line-height:1.72}.ycp h2{margin:44px 0 17px;color:#102a43;font-size:31px;line-height:1.25}.ycp h3{margin:26px 0 8px;color:#174a71;font-size:21px}.ycp a{color:#087e8b;text-decoration:underline;text-underline-offset:3px}.ycp .answer{padding:24px 28px;border-left:5px solid #168aad;background:#eef9fc;font-size:19px}.ycp .reviewed{color:#64748b;font-size:14px}.ycp .facts{display:grid;grid-template-columns:repeat(4,1fr);gap:15px;margin:28px 0}.ycp .fact{padding:20px 17px;border:1px solid #d7e3ec;border-radius:10px}.ycp .fact strong{display:block;color:#087e8b;font-size:20px}.ycp table{width:100%;border-collapse:collapse;margin:22px 0}.ycp th,.ycp td{padding:13px 15px;border:1px solid #d8e2ea;text-align:left;vertical-align:top}.ycp th{background:#16324f;color:#fff}.ycp .box{padding:22px 28px 22px 46px;border-radius:10px;background:#f3f6f9}.ycp .note{padding:19px 23px;border-left:4px solid #e9a23b;background:#fff7e6}.ycp .steps{counter-reset:s;display:grid;grid-template-columns:1fr 1fr;gap:16px;padding:0;list-style:none}.ycp .steps li{position:relative;padding:20px 20px 20px 62px;border:1px solid #d7e3ec;border-radius:10px}.ycp .steps li:before{counter-increment:s;content:counter(s);position:absolute;left:18px;top:19px;width:31px;height:31px;border-radius:50%;background:#168aad;color:#fff;text-align:center;line-height:31px;font-weight:700}.ycp .cta{margin-top:42px;padding:28px;border-radius:12px;background:#102a43;color:#fff}.ycp .cta h2{margin-top:0;color:#fff}.ycp .cta a{display:inline-block;margin:8px 10px 0 0;padding:11px 18px;border-radius:6px;background:#17a2b8;color:#fff;text-decoration:none;font-weight:700}@media(max-width:760px){.ycp .facts,.ycp .steps{grid-template-columns:1fr 1fr}.ycp h2{font-size:27px}.ycp table{display:block;overflow-x:auto}}@media(max-width:520px){.ycp .facts,.ycp .steps{grid-template-columns:1fr}.ycp{padding-left:14px;padding-right:14px}}\n<\/style>\n<div class=\"ycp\">\n<p class=\"answer\"><strong>Power bank compliance is model-specific, market-specific, and sensitive to design changes.<\/strong> CE, FCC, RoHS, UN 38.3, IEC 62133-2, China CCC, and Qi or Qi2 address different legal, transport, safety, o interoperability requirements. Before ordering, verify the exact model, report scope, issuing body, applicable standard, and current document status.<\/p>\n<div class=\"facts\">\n<div class=\"fact\"><strong>Product-specific<\/strong>Evidence for one battery, PCBA, coil, firmware, o housing may not cover another.<\/div>\n<div class=\"fact\"><strong>Espec\u00edfico del mercado<\/strong>EU, US, China, transport, retailer, and wireless requirements follow different paths.<\/div>\n<div class=\"fact\"><strong>Change-sensitive<\/strong>Design, firmware, branding, o model changes may require review or re-testing.<\/div>\n<div class=\"fact\"><strong>Verifiable<\/strong>Check report IDs, laboratories, models, dates, and official databases\u2014not logos alone.<\/div>\n<\/div>\n<h2>What Do the Main Power Bank Compliance Documentos Cover?<\/h2>\n<table>\n<thead>\n<tr>\n<th>Requisito<\/th>\n<th>Finalidad<\/th>\n<th>What Buyers Should Verify<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Marcado CE<\/strong><\/td>\n<td>The manufacturer&#8217;s declaration that a product meets applicable EU requirements; it is not a general EU approval.<\/td>\n<td>EU Declaraci\u00f3n de Conformidad, relevant legislation and standards, matching model, technical reports, and responsible economic operator.<\/td>\n<\/tr>\n<tr>\n<td><strong>RoHS<\/strong><\/td>\n<td>EU restrictions on specified hazardous substances in electrical and electronic equipment.<\/td>\n<td>Test or matterial evidence, model and bill-of-matterial scope, supplier declarations, and any exemptions used.<\/td>\n<\/tr>\n<tr>\n<td><strong>FCC<\/strong><\/td>\n<td>US radio-frequency requirements. The route depends on the product&#8217;s functions; wireless power may involve Part 15, Part 18, o both.<\/td>\n<td>Rule part, FCC ID when certification applies, SDoC information where applicable, test report, responsible party, and operating modes.<\/td>\n<\/tr>\n<tr>\n<td><strong>UN 38.3<\/strong><\/td>\n<td>Lithium-cell and battery transport testing under the UN Manual of Tests and Criteria.<\/td>\n<td>Manufacturer, laboratory, report number and date, model, Wh rating, tests and results, manual revision, and signature in the test summary.<\/td>\n<\/tr>\n<tr>\n<td><strong>IEC 62133-2<\/strong><\/td>\n<td>Safety requirements and tests for portable sealed secondary lithium cells and batteries.<\/td>\n<td>The exact cell or pack model, report edition and amendment, laboratory, report number, and relationship to the finished product.<\/td>\n<\/tr>\n<tr>\n<td><strong>CCC de China<\/strong><\/td>\n<td>Mandatory certification for products in the applicable China catalogue, including mobile power supplies.<\/td>\n<td>Certificado number and status, legal manufacturer and site, product model, applicable GB standards, certification mark, and traceability details.<\/td>\n<\/tr>\n<tr>\n<td><strong>Qi \/ Qi2<\/strong><\/td>\n<td>WPC certification for a finished wireless-charging product&#8217;s interoperability and performance.<\/td>\n<td>WPC ID, brand, product name, part number, power profile, certification date, and matching official database listing.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Documentos to Request Before a Bulk Order<\/h2>\n<ul class=\"box\">\n<li>Final specification showing model, battery Wh, charging protocol, rated input and output, wireless power, ports, cables, and firmware.<\/li>\n<li>Laboratory, report number, issue date, applicable standard and edition, test result, and certificate status.<\/li>\n<li>Resumen de ensayos UN 38.3 for the battery type used in the shipment.<\/li>\n<li>EU Declaraci\u00f3n de Conformidad and supporting technical evidence for EU orders.<\/li>\n<li>CCC certificate and matching model information for products within China&#8217;s compulsory scope.<\/li>\n<li>WPC listing and WPC ID before using the terms Qi Certified or Certificaci\u00f3n Qi2.<\/li>\n<li>Change-control record covering the approved battery, PCBA, coil, magnets, housing, firmware, and electrical ratings.<\/li>\n<\/ul>\n<h2>When Can a Design Change Affect Existing Evidence?<\/h2>\n<p>A new battery cell, protection circuit, charging IC, PCBA layout, wireless coil, magnet, shielding matterial, firmware, housing, cable, connector, rated power, brand, o model number may require formal review or re-testing. A component used in a previously tested design does not automatically make a different finished product compliant.<\/p>\n<p class=\"note\"><strong>Important:<\/strong> \u201cCompatible with Qi,\u201d \u201cuses a Qi chipset,\u201d and \u201cQi Certified\u201d are different claims. Describe a finished product as Qi Certified or Certificaci\u00f3n Qi2 only when the WPC certification and database entry match it.<\/p>\n<h2>How YULIDA Reviews a Compliance Request<\/h2>\n<ol class=\"steps\">\n<li><strong>Confirm the market<\/strong><br \/>Identify target, sales channel, shipment method, claims, and required date.<\/li>\n<li><strong>Lock the specification<\/strong><br \/>Documento the battery, PCBA, ports, power, wireless functions, firmware, housing, and model.<\/li>\n<li><strong>Map requirements<\/strong><br \/>Match the configuration to product, transport, EMC, matterial, and wireless rules.<\/li>\n<li><strong>Review evidence<\/strong><br \/>Compare reports with the sample and arrange testing when the scope does not match.<\/li>\n<li><strong>Release documents<\/strong><br \/>Provide current files for the approved order, with redaction where appropriate.<\/li>\n<li><strong>Control changes<\/strong><br \/>Review substitutions before production against the approved specification.<\/li>\n<\/ol>\n<h2>Preguntas frecuentes<\/h2>\n<h3>Are all YULIDA power bank models covered by the same certificates?<\/h3>\n<p>No. Evidence depends on the model, battery, PCBA, functions, target market, and production configuration. Request the package matching the quoted model and approved sample.<\/p>\n<h3>Is UN 38.3 enough for air shipment?<\/h3>\n<p>No. Shippers must also follow current carrier, packaging, state-of-charge, labelling, documentation, and dangerous-goods rules for the route.<\/p>\n<h2>Fuentes oficiales de referencia<\/h2>\n<ul class=\"box\">\n<li><a href=\"https:\/\/europa.eu\/youreurope\/business\/product-requirements\/labels-markings\/ce-marking\/index_en.htm\" target=\"_blank\" rel=\"noopener noreferrer\">Uni\u00f3n Europea: Marcado CE<\/a><\/li>\n<li><a href=\"https:\/\/environment.ec.europa.eu\/topics\/waste-and-recycling\/rohs-directive_en\" target=\"_blank\" rel=\"noopener noreferrer\">Comisi\u00f3n Europea: Directiva RoHS<\/a><\/li>\n<li><a href=\"https:\/\/www.fcc.gov\/oet\/ea\/rfdevice\" target=\"_blank\" rel=\"noopener noreferrer\">US FCC: Radio-frequency device authorization<\/a><\/li>\n<li><a href=\"https:\/\/unece.org\/transport\/dangerous-goods\/rev8-files\" target=\"_blank\" rel=\"noopener noreferrer\">UNECE: UN Manual of Tests and Criteria<\/a><\/li>\n<li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/32662\" target=\"_blank\" rel=\"noopener noreferrer\">IEC: IEC 62133-2<\/a><\/li>\n<li><a href=\"https:\/\/www.cnca.gov.cn\/zwxx\/gg\/2023\/art\/2023\/art_9b1f71e55d06483d9cbdd35e791a4e60.html\" target=\"_blank\" rel=\"noopener noreferrer\">CNCA: CCC requirements for lithium-ion batteries and power banks<\/a><\/li>\n<li><a href=\"https:\/\/www.wirelesspowerconsortium.com\/products\/\" target=\"_blank\" rel=\"noopener noreferrer\">Wireless Power Consortium: certified product database<\/a><\/li>\n<\/ul>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>A practical B2B guide to CE, FCC, RoHS, UN 38.3, IEC 62133-2, China CCC, and Qi or Qi2 requirements for power bank sourcing.<\/p>","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"om_disable_all_campaigns":false,"footnotes":""},"class_list":["post-17187","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.yulidapower.com\/es\/wp-json\/wp\/v2\/pages\/17187","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.yulidapower.com\/es\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.yulidapower.com\/es\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.yulidapower.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.yulidapower.com\/es\/wp-json\/wp\/v2\/comments?post=17187"}],"version-history":[{"count":18,"href":"https:\/\/www.yulidapower.com\/es\/wp-json\/wp\/v2\/pages\/17187\/revisions"}],"predecessor-version":[{"id":17568,"href":"https:\/\/www.yulidapower.com\/es\/wp-json\/wp\/v2\/pages\/17187\/revisions\/17568"}],"wp:attachment":[{"href":"https:\/\/www.yulidapower.com\/es\/wp-json\/wp\/v2\/media?parent=17187"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}